ECOFLUX 
IFM 1010 K 
IFM 1080 K 

AQUAFLUX 
010 K 
080 k 

ALTOFLUX 
IFM 4010 K 
IFM 4080 K 

*hazardous duty version only with IFC 090 signal converter   

**in preparation  

Teflon® is a registered trademark of DuPont

 
. 
Characterization
. 
Flangeless version
Rugged measuring tube with stainless steel reinforced Teflon® PFA liner
Particularly economical
Wide filed of application
 
. 
Flanged connections, steel housing
µP-signal converter in plastic housing
Available with or with out indicator
Particularly economical
. 
.
. 
Flanged connections, steel housing
Teflon © PFA liner, reinforced with stainless steel mesh, for high chemical, vacuum and abrasion resistance
 
Signal converter IFC 010 K or IFC 090 K IFC 010 K or IFC 090 K IFC 010 K or IFC 090 K
Electrical conductivity 5µS/cm (water  20 µS/cm) 20 µS/cm 5 µS/cm (water  20 µS/cm)
Full scale range 
(0.3-12m/s) (1-40 ft/s)
85 liter/h - 760 m3/h
0.3 - 3 360 US Gal/min
85 liter/h - 33 000 m3/h
0.3 - 156 000 US Gal/min
85 liter/h - 33 000 m3/h
0.3 - 156 000 US Gal/min
Meter size DN 10 - 150 and 3/8" - 6" DN 10 - 1000 and 3/8" - 40" DN 10 - 1000 and 3/8" - 40"
Pressure rating up to 16 bar/230 psig up to 40 bar/580 psig up to 40 bar/580 psig
Product temperature - 25 to + 120ºC/- 13 to + 248ºF - 5 to + 90 ºC/+ 23 to + 194ºF - 60 to + 140 ºC/- 75 to + 284ºF
Protection category IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6
Materials
(others on
request) electrodes
Teflon®PFA

Hastelloy C4

DN 25 /  1" hard rubber
DN 20 /  ¾" Teflon® PTFE
Hastelloy C4
Teflon® PFA, Teflon® PTFE
ETFE (Tefzel)
Hastelloy C4, platinum, titanium
stainless steel 1.4571/316 Ti.
Hazardous Euro. Std.
duty
versions*FM-Factory Mutual
no
 

no

no



no
EEx dqe or dq ib IIC T3 . . .  T6
Class I, II, III, Div 1, 2**
Fields of application
Industry environmental engineering water and sewage, agriculture, batching of fertilizers and liquids feeds environmental engineering, 
water and sewage
the "workhorse" for water, sewage and waste water, chemicals, paper, cellulose, ore dressing
Abrasion resistance very good higher than required for the applications in question dependent on liner material, very high with Teflon® PFA
Chemical resistance
of liner
...with alakis, eg. NaOH
NaOH up to 70 % at 20ºC/68ºF NaOH up to 50 % at 20 ºC/68 ºF all concentrations with Teflon® PFA or PTFE liners
...with acids, eg. HNO3 HNO3 up to 65 % at 20 ºC/68 ºF HNO3 up to 5 % at 20 ºC/68 ºF all concentations with Teflon® PFA or PTFE liners
(limited by electrode material) (select materials for grounding rings and gaskets for process compatibility)
.
 